DefiXpress Defibrillator Technical Specification
Meditech Debrillator Monitor can work both in Automated External Debrillator (AED) mode and Manual mode and record parameters of ECG, HR and SpO2. Features: ·
Works both in automated external debrillator (AED) and Manual modes · Records ECG, HR and SpO2 · It has voice and visual prompts for charge prompt and shockable rhythm · It has a high-resolution display and a thermal printer
| Display: | 7 screen(17.7cm)diagonally |
| Sweep speed: | 25mm/ sec |
| Number of leads for ECG: | 3-lead ECG cable or 5-lead ECG cable, paddles |
| Output: | Biphasic |
| Energy sequence: | Monitor display indicates both selected and delivered energy |
| Charge time: | <7sec with a new fully charged battery |
| Charge prompts: | Voice and visual prompts |
| Electrode impedance measurement range: | 0-250Ω |
| Lead selection: | Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V |
| ECG size: | 0.25, 0.5, 1, 1.5, 2, 4 cm/mV display on monitor |
| Heart rate: | 20-300bpm |
| Heart rate alarm: | On/Off displayed on monitor, user-selectable |
| Smart alarm: | Beeper/voice prompts indicate shockable rhythm |
| SpO2 measurement range: | 30~100%, ±2% between 80%~90%, others ±5% |
| Alarm range for SpO2 measurement range: | User set high limit and low limit |
| Alarm accuracy for SpO2 measurement range: | ±10% within setting values |
| Alarm time accuracy for SpO2 measurement range: | Less than 12secs |
| Functions of AED mode: | Auto analyse and charge x3 with programmable auto energy level selection, screen prompts, and voice prompts |
| Shockable rhythms of AED mode: | Ventricular fibrillation with amplitude >=200uV ventricular tachycardia with rates >=140bpm QRS complex wave duration >=140ms |
| Charge control of AED mode: | Control on device front panel, press key on paddle |
| Prompts of AED mode: | Voice and visual prompts |
| Energy selection of Manual mode: | Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules |
| Synchronization of Manual mode: | Synchronizes defibrillator pulse to patient's R-wave. ”SYNC” message displayed on monitor |
| Printer paper: | 50mm thermal paper |
| Paper speed: | 12.5mm/sec, 25mm/sec, 50mm/sec. User-selectable 6-second delay |
| Printing method: | High-resolution, thermal print head |
| Print-out modes: | Manual or automatic, user-configurable |
| On/Off control: | Front panel and paddle |
| Automatic function: | 9-seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge |
| Battery: | Rechargeable, Ni-MH battery, 12V |
| Battery life: | For a new, fully charged battery- 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operating time with different functions |