Handheld patient monitor with SpO₂, pulse rate, temperature monitoring & advanced data review
The Oxima5 Portable Patient Monitor is a portable multi-parameter monitor designed for accurate measurement of SpO₂, Pulse Rate (PR), and Temperature (TEMP). Equipped with a high-contrast color screen, waveform visualization, alarm management, trend review, and long battery operation, it provides reliable monitoring for hospitals, clinics, emergency care, and bedside applications.
With flexible sensor options and a compact design, the Oxima5 supports the monitoring needs of adults, children, and neonates while providing essential vital signs information to clinical physicians for effective patient care.
All Meditech customers and healthcare professionals can submit equipment service tickets through the Customer Service Portal.
To receive two additional months of extended warranty, please register your product here.To browse all support resources and contact information, please visit the Support Center.
Coming soon.
Discover the advanced capabilities that set our products apart
Detailed technical specifications and performance parameters
| Parameter | Specifications |
|---|---|
| Measurement Range | 0–100% |
| Alarm Range | 0–100% |
| Resolution | 1% |
| Accuracy | 70–100%: ±2% 0–69%: Unspecified |
| Update Interval | Approximately 1 second |
| Alarm Delay | 10 s |
| Pulse Rate Range | 0–254 bpm |
| Pulse Rate Resolution | 1 bpm |
| Pulse Rate Accuracy | ±2 bpm |
| Parameter | Specifications |
|---|---|
| Measurement Method | Oscillometric |
| Measurement Modes | Manual / Automatic / STAT |
| Automatic Measurement Interval | 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480 minutes |
| STAT Mode Duration | 5 minutes |
| Pulse Rate Range | 40–240 bpm |
| Alarm Type | SYS, DIA, Mean |
| Adult Mode | SYS: 40–270 mmHg DIA: 10–215 mmHg Mean: 20–235 mmHg |
| Pediatric Mode | SYS: 40–200 mmHg DIA: 10–150 mmHg Mean: 20–165 mmHg |
| Neonatal Mode | SYS: 40–135 mmHg DIA: 10–100 mmHg Mean: 20–110 mmHg |
| Resolution | 1 mmHg |
| Accuracy | Mean Deviation ≤ ±5 mmHg Standard Deviation ≤ ±8 mmHg |
| Overpressure Protection | Adult: 297 ±3 mmHg Pediatric: 240 ±3 mmHg Neonatal: 147 ±3 mmHg |
| Parameter | Specifications |
|---|---|
| Channel | Single Channel |
| Measurement & Alarm Range | 0–50°C |
| Resolution | 0.1°C |
| Accuracy | ±0.1°C |
| Update Interval | Approximately 1 second |
| Average Time Constant | <10 s |
Compatible accessories to extend functionality
| Item | Quantity |
|---|---|
| ECG cable (5 leads) | 1 piece |
| SpO₂ cable (adult) | 1 piece |
| TEMP probe (adult) | 1 piece |
| NIBP cuff (adult) | 1 piece |
| NIBP tube (150 cm) | 1 piece |
| Grounding cable | 1 piece |
| Power cable | 1 piece |
| Cleaning cloth | 1 piece |
| Item |
|---|
| ECG cable (3 leads) |
| ECG alligator clips (metal) |
| SpO₂ cable (adult rigid shell sensor) |
| SpO₂ cable (adult soft shell sensor) |
| SpO₂ cable (neonatal soft sensor) |
| SpO₂ cable (pediatric rigid shell sensor) |
| SpO₂ cable (pediatric soft shell sensor) |
| SpO₂ cable (pediatric finger clip) |
| SpO₂ cable (multi-site Y-type) |
| External SpO₂ cable |
| NIBP cuff (infant 8–14 cm, 5/bag) |
| NIBP cuff (pediatric 13–20 cm, 5/bag) |
| NIBP cuff (small adult 18–26 cm, 5/bag) |
| NIBP cuff (adult 26–35 cm, 5/bag) |
| NIBP cuff (tall adult 29–38 cm, 5/bag) |
| NIBP cuff (large adult 32–42 cm, 5/bag) |
| NIBP cuff (tall large adult 35–44 cm, 5/bag) |
| NIBP cuff (thigh 42–50 cm) |
| NIBP tube (150 cm) |
Core specifications at a glance