Detailed technical specifications and performance parameters
| Parameter | Specifications |
|---|---|
| Diagnostic Frequency Options | Diagnostic filter 0.05–150 Hz |
| Filtered Diagnostic Mode | 0.05–40 Hz |
| Frequency Response | User-selectable frequency response |
| Parameter | Specifications |
|---|---|
| Output Waveform | Biphasic Truncated Exponential (BTE) waveform |
| Tested Load Range | Resistive loads 25Ω, 50Ω and 100Ω |
| Waveform Accuracy | Output waveform parameters within ±10% |
| Load Condition | Accuracy |
|---|---|
| 50Ω Load | ±10% or 1J, whichever is greater |
| Load 25–100Ω | ±15% or 1J, whichever is greater |
| Parameter | Specifications |
|---|---|
| External Energy Levels | 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 J |
| Parameter | Specifications |
|---|---|
| Charge Time | Less than 6 seconds at 200J using a Meditech Ni-MH 12V battery |
| Charge Time After 15 Discharges | Less than 12 seconds at 360J |
| Charge Time Using AC Power | Less than 15 seconds at 360J with AC voltage at 90% of nominal voltage |
| Parameter | Specifications |
|---|---|
| Screen Type | 8-inch color TFT screen |
| Resolution | 800 × 600 pixels |
| Patient Input | 3-wire and 5-wire patient cable |
| Parameter | Specifications |
|---|---|
| Sweep Speed | 12.5 / 25 / 50 mm/s |
| Lead Selection | I, II, III, aVR, aVL, aVF, V |
| Frequency Response – Operating Mode | 0.7–20 Hz |
| Frequency Response – Monitoring Mode | 0.3–40 Hz |
| Frequency Response – Diagnostic Mode | 0.05–150 Hz |
| Frequency Response – AED Mode | 0.5–30 Hz |
| Common Mode Rejection Ratio (CMRR) | ≥60 dB |
| Heart Rate Range | 20–300 bpm |
| Heart Rate Alarm Limits | User-selectable |
| Parameter | Specifications |
|---|---|
| ECG Size | 0.125 / 0.25 / 0.5 / 1 / 2 / 4 cm/mV |
| Auto Range Function | Supported |
| ECG Output | 1 V/mV |
| Parameter | Specifications |
|---|---|
| Audible Alarm | 5 pulses, 800 Hz tone |
| Visual Alarm | Heart rate display flashes at 2 Hz |
| Parameter | Specifications |
|---|---|
| Audible alarm | Triple tone |
| Visual indicator | "Lead fault" message |
| Additional indicator | Wave loss indicator |
| Parameter | Specifications |
|---|---|
| Measurement method | Automatic oscillometric measurement (Oscillometric) |
| Measurement modes | Manual / Automatic |
| Adult range | 10–250 mmHg |
| Pediatric range | 10–200 mmHg |
| Neonatal range | 10–135 mmHg |
| Parameter | Specifications |
|---|---|
| Electrical Protection Class | BF |
| Power Source | 12.0V ±0.2V DC |
| Current Consumption | Typical 100mA / Maximum 200mA |
| Operating Temperature | 5°C to 50°C |
| Storage Temperature | -20°C to 70°C |
| Humidity | 0–85% RH, non-condensing |
| Dimensions | 96 × 91 × 36 mm |
| CO₂ Measurement Range | 0–13% |
| Accuracy | ±3 mmHg or less than ±10% of reading |
| Respiration Rate Range | 3–60 bpm |
| Respiration Rate Accuracy | ±1 bpm |
| Warm-up Time | 10 seconds |
| Flow Rate | 50-250 mL/min |
| Interface | TTL / RS232, digital serial interface |
| Parameter | Specifications |
|---|---|
| Type | VVI |
| Pulse waveform | Constant-current rectangular wave |
| Output current | 0–180 mA, ±10% or 5 mA |
| Pacing rate | 30–180 ppm |
| Accuracy | ±1.5% |
| Electrodes | Multifunction defibrillation and pacing electrodes |
| Pulse width | 20 ±1.5 ms |
| Output protection | Fully isolated and defibrillation-protected |
| Parameter | Specifications |
|---|---|
| Type | High-precision thermal recorder |
| Recorded data | Date and time |
| ECG waveform | |
| ECG derivation | |
| Gain | |
| Heart rate | |
| Defibrillation events | |
| Treatment summary | |
| ACLS events |
Compatible accessories to extend functionality
| Item | Quantity |
|---|---|
| ECG Cable (5 Leads) | 1 Piece |
| AED Adapter Pad | 1 Piece |
| AED Pad | 1 Piece |
| Grounding Cable | 1 Piece |
| Power Cable | 1 Piece |
| Thermal Paper Roll | 1 Piece |
| Cleaning Cloth | 1 Piece |
| Item |
|---|
| AED Pad for Child |
| ECG Cable (3 Leads) |
| ECG Alligator Clips (Metal) |
| SpO₂ Cable (Adult Hard Shell Sensor) |
| SpO₂ Cable (Adult Soft Shell Sensor) |
| SpO₂ Cable (Neonatal Soft Sensor) |
| SpO₂ Cable (Pediatric Hard Shell Sensor) |
| SpO₂ Cable (Pediatric Soft Shell Sensor) |
| SpO₂ Cable (Pediatric Finger Clip) |
| SpO₂ Cable (Y-Type Multi-Site) |
| External SpO₂ Cable |
| Item |
|---|
| NIBP Cuff (Infant 8–14 cm, 5 Pieces/Bag) |
| NIBP Cuff (Pediatric 13–20 cm, 5 Pieces/Bag) |
| NIBP Cuff (Small Adult 18–26 cm, 5 Pieces/Bag) |
| NIBP Cuff (Adult 26–35 cm, 5 Pieces/Bag) |
| NIBP Cuff (Long Adult 29–38 cm, 5 Pieces/Bag) |
| NIBP Cuff (Large Adult 32–42 cm, 5 Pieces/Bag) |
| NIBP Cuff (Large Long Adult 35–44 cm, 5 Pieces/Bag) |
| NIBP Cuff (Thigh 42–50 cm) |
| NIBP Tube 150 cm |
| Paper Roll |
| Item |
|---|
| Defibrillator Wall Mount (3 Models Available) |
| Defibrillator Cart (5 Models Available) |
| Defibrillator Carry Case |
| EtCO₂ Module |
| IrDA USB Adapter for ECG Data Transfer |
| ECG Data Transfer Software CD |
Core specifications at a glance
Defixpress defibrillator-monitor, intended for use primarily in emergency situations associated with the risk of cardiac arrest in a patient
Read moreMeditech Defibrillator pad features include: Multifunction Defibrillation Electrodes are designed for the use of external defibrillation, non-invasive pacing, synchronized cardioversion and monitoring on adults and children weighing more than 20 kg (55 lbs)
Read moreDefi Xpress Desfibrilador Caracteristicas: limagesrl Visualizacion Tipo de pantalla: pantalla de alta resolución Tamaño de pantalla: 17,7 cm (7 pulgadas) diagonalmente Velocidad de barrido: 25 mm/sInformación: ritmo cardíaco, derivaciones/almohadillas, alarma encendida/apagada, funciones AED y avisos, selección de alarmas y límites, energía suministrada limagesrl Módulo SP02 Rango de medición: 30-100%, ± 2% entre el 80%-90%, otros ± 5% Rango de alarma: los límites inferior e inferior configurables por el usuario Precisión de la alarma: ± 10% dentro de los valores de configuraciónPrecisión del tiempo de alarma: menos de 12 s limagesrl Desfibrilador Forma de onda: bifásica Visualización de energía: la pantalla indica la energía seleccionada y la suministrada Tipo de aviso de carga: avisos de voz y visualesRango de medición de la impedancia de electrodos: 0-250 ohms limagesrl Registrador Papel: 50 mm térmico Velocidad: 12,5 mm/s; 25 mm/s; 50 mm/s
Read moreProduk Jual Defibrilator Defixpress merupakan perangkat defibrilator yang dapat memenuhi kebutuhan klinis anda, Produk Defibrilator ini Impor Dari China dan garansi 1 Tahun
Read moreESCRIPTION RAPIDE Affichage Type d'écran: Écran haute résolution Taille de l'écran: 7 pouces (17,7 cm) en diagonale Balayer Vitesse: 25mm / sec Information: fréquence cardiaque, de plomb / Pads, alarme On / Off, SpO2, Fonctions AED et Aller, sélection et limites d'alarme, l'énergie délivrée
Read moreCaracteristici Tip ecran: Display color de inalta rezolutie, 800x600 pixeli Dimensiune ecran: 7 inch (17
Read moreTipo : EEG/ECG/EKG/EMG/VCG Digital Clasificación : Funciones Fisiológicas de Diagnóstico y Equipos para el Monitoreo Descripción de Producto Defixpress es un dispositivo de la desfibrilación, que puede cubrir sus necesidades clínicas del conectado a una máquina que mantiene las constantes vitales básico (BLS) al conectado a una máquina que mantiene las constantes vitales cardiaco avanzado (ACLS)
Read moreGIỚI THIỆU Khi Defi Xpress làm việc trong chế độ MANUAL, nó phan tích dạng sóng ECG của bệnh nhan, để cho thấy nhịp tim
Read more